TLS wall mount series AC automatic voltage stabilizer , which is the leading select of the American chip by our company for the circuit board .This wall mount voltage regulator can do with RELAY CONTROL or SERVO MOTOR CONTROL ,because this one with the large internal space .
Fluctuations of the voltage in the electrical network above the permissible norms lead to negative consequences for electronic and electrical equipment.AC voltage stabilizers are intended to provide a quality and secure work of different devices under conditions of unstable voltage .
This series of voltage stabilizers are developed in appliance with international standards for protection from emergency power surges,beginning with city apartments and ending with large residential and production complexes.
THE ADVANTAGES OF THIS MODEL:
1.Wide input voltage:AC 140~260V or 100-260VAC Or customize
2.High technology:programmed control computerized
3.Fashion design:LED display which can show all protection functions.
4.Quality insurance:Main spare parts made by ourselves,for example,transformer,PCB.
5.Perfect protection function:over/low voltage protection,over-heat/load protection,short circuit protection.
6.Option function:with voltage regulator and mains supply two kind output voltage choice function,in mains supply relatively stable season,the user can put voltage stabilizer in mains supply state,there is no power consumption,it is economic and convenient.
7.High efficiency:More than 95%
SPECIFICATIONS
TLS-500VA/1000VA/1500VA/2000VA/3000VA/5000VA/8000VA/10000VA | |
Input voltage | 140-260v/100-260v Or customize |
Input frequnency | 50/60Hz |
Output voltage | 220V AC/110V AC |
Output precision | 220V+/-8%,110V+/-10% |
Time delay | 6’s short time,180’s long time |
Efficiency: | >95% |
Load power factor | 0.8 |
Phase | single phase |
Operating temperature | 0-40℃ |
Storage temperature | -15℃-45℃ |
Operating relative humidity | 10%RH-102%RH |
Customize option for specification and availability please contact TAILEI |
DIMENSION WEIGHT
MODEL | QTY/CTN | MEAS(cm) | G.W.(kg) | N.W.(kg) | COMTAINER20(PCS) |
TLS-500VA | 4 | 53*27*32 | 12 | 11 | 2400 |
TLS-1000VA | 4 | 53*27*32 | 15.4 | 14.4 | 2400 |
TLS-1500VA | 4 | 53*27*32 | 19 | 18 | 2400 |
TLS-2000VA | 4 | 53*27*32 | 21 | 20 | 2400 |
TLS-3000VA | 2 | 69*30*24 | 17.5 | 16.5 | 800 |
TLS-5000VA | 2 | 69*30*24 | 24 | 22.6 | 800 |
TLS-8000VA | 1 | 44*37*24 | 16.5 | 15.5 | 700 |
TLS-10000VA | 1 | 44*37*24 | 18.8 | 17.6 | 700 |
PRECAUTIONS:
1. The voltage of network input must conform to the demand of AVR, for optimum operation.2. Connect all plugs securely.3. Always turn AVR power switch on first, the turn appliance power switch on.(Failure to do so may cause AVR fuse to blow)4. For best results, do not use if overload condition exists.5. Do not use in overly humid or flammable surroudings; avoid contact with any liquids.6. The relationship between the output capacity and input voltage as following picture and diagram: | ![]() |
Overload | Utmost using time |
20% | 60 minutes |
40% | 32 minutes |
60% | 5 minutes |
Long time overload is forbidden.
TLS wall mount series AC automatic voltage stabilizer , which is the leading select of the American chip by our company for the circuit board .This wall mount voltage regulator can do with RELAY CONTROL or SERVO MOTOR CONTROL ,because this one with the large internal space .
Fluctuations of the voltage in the electrical network above the permissible norms lead to negative consequences for electronic and electrical equipment.AC voltage stabilizers are intended to provide a quality and secure work of different devices under conditions of unstable voltage .
This series of voltage stabilizers are developed in appliance with international standards for protection from emergency power surges,beginning with city apartments and ending with large residential and production complexes.
THE ADVANTAGES OF THIS MODEL:
1.Wide input voltage:AC 140~260V or 100-260VAC Or customize
2.High technology:programmed control computerized
3.Fashion design:LED display which can show all protection functions.
4.Quality insurance:Main spare parts made by ourselves,for example,transformer,PCB.
5.Perfect protection function:over/low voltage protection,over-heat/load protection,short circuit protection.
6.Option function:with voltage regulator and mains supply two kind output voltage choice function,in mains supply relatively stable season,the user can put voltage stabilizer in mains supply state,there is no power consumption,it is economic and convenient.
7.High efficiency:More than 95%
SPECIFICATIONS
TLS-500VA/1000VA/1500VA/2000VA/3000VA/5000VA/8000VA/10000VA | |
Input voltage | 140-260v/100-260v Or customize |
Input frequnency | 50/60Hz |
Output voltage | 220V AC/110V AC |
Output precision | 220V+/-8%,110V+/-10% |
Time delay | 6’s short time,180’s long time |
Efficiency: | >95% |
Load power factor | 0.8 |
Phase | single phase |
Operating temperature | 0-40℃ |
Storage temperature | -15℃-45℃ |
Operating relative humidity | 10%RH-102%RH |
Customize option for specification and availability please contact TAILEI |
DIMENSION WEIGHT
MODEL | QTY/CTN | MEAS(cm) | G.W.(kg) | N.W.(kg) | COMTAINER20(PCS) |
TLS-500VA | 4 | 53*27*32 | 12 | 11 | 2400 |
TLS-1000VA | 4 | 53*27*32 | 15.4 | 14.4 | 2400 |
TLS-1500VA | 4 | 53*27*32 | 19 | 18 | 2400 |
TLS-2000VA | 4 | 53*27*32 | 21 | 20 | 2400 |
TLS-3000VA | 2 | 69*30*24 | 17.5 | 16.5 | 800 |
TLS-5000VA | 2 | 69*30*24 | 24 | 22.6 | 800 |
TLS-8000VA | 1 | 44*37*24 | 16.5 | 15.5 | 700 |
TLS-10000VA | 1 | 44*37*24 | 18.8 | 17.6 | 700 |
PRECAUTIONS:
1. The voltage of network input must conform to the demand of AVR, for optimum operation.2. Connect all plugs securely.3. Always turn AVR power switch on first, the turn appliance power switch on.(Failure to do so may cause AVR fuse to blow)4. For best results, do not use if overload condition exists.5. Do not use in overly humid or flammable surroudings; avoid contact with any liquids.6. The relationship between the output capacity and input voltage as following picture and diagram: | ![]() |
Overload | Utmost using time |
20% | 60 minutes |
40% | 32 minutes |
60% | 5 minutes |
Long time overload is forbidden.