AVR/SVR series single phase RELAY CONTROL AC automatic voltage regulator , which is the classic style voltage regulator with analogue meter.It has the low energy consumption, the over-voltage protection, the low voltage protection, the over- current protection, the over-power protection, the over-temperature protection, the leakage protection and so on. It boasts for many kinds of protection functions integrated to one product. It also has the following functions: the selective time delay, the anti- impact, the Analogue display, the collection energy conservation and the environmental protection etc. This is a brand-new concept product which possess many new technologies! This series products simultaneously has applied for many technical monopolies.
FEATURES:
FEATURE : | Automatic voltage regulation Wide Input Voltage Range Large Capacity, High precision Protection against brownouts & over voltage Short circuit protection Analog indicators to show status of working,unusual and delaying Selectable delay time Build-in transformer:Toroidal transformer, E transformer selectable No Additional Waveform Distortion Global Voltage Customization |
APPLICATIONS: | TV-SET / HI-FI / DVD / FAX / Copy Machine / Printer/ Scanner /Air Conditioner/Computer /Test Equipment/Fridge /Lighting/ Equipment ETC |
PERFORMANCE AND SPECIFICATION:
Model | SVR-500 | SVR-1000 | SVR-1500 | SVR-2000 | SVR-3000 | SVR-5000 | |
Rated Capacity | 500VA | 1000VA | 1500VA | 2000VA | 3000VA | 5000VA | |
Phase | Single | ||||||
Transformer | E square transformer | ||||||
Indicator | analog meter | ||||||
Display Status | voltage and current | ||||||
Input | Voltage | 80~260 Vac | |||||
Frequency | 50/60 Hz | ||||||
Output | Voltage | 110/120/220/230/240 Vac optional | |||||
Precision | ±8% | ||||||
Protection | Overload | Yes | |||||
High temperature | Yes | ||||||
High/low voltage | Yes | ||||||
Short circuit | Yes | ||||||
Delay Function | delay / un-delay (180/6 seconds selectable) | ||||||
Efficiency | 98% | ||||||
Cooling system | Smart cooling | ||||||
Environmental | Operating temperature | 0 ~ 40 °C | |||||
Relative humidity | 10%~102% RH, non-condensing | ||||||
Storage temperature | -15 ~ 45 °C | ||||||
Appearance | AVR size (mm) | 240*125*155 | 340*205*255 | ||||
AVR N.W. (kg) | 2.60 | 2.80 | 3.50 | 3.80 | 8.50 | 10.00 | |
Qty/Ctn | 4 | 2 | |||||
Carton size (mm) | 550*300*190 | 510*390*300 | |||||
Carton G.W. (kg) | 10.50 | 11.50 | 14.20 | 15.50 | 17.50 | 20.50 |
PRECAUTIONS:
1. The voltage of network input must conform to the demand of AVR, for optimum operation. 2. Connect all plugs securely. 3. Always turn AVR power switch on first, the turn appliance power switch on.(Failure to do so may cause AVR fuse to blow) 4. For best results, do not use if overload condition exists. 5. Do not use in overly humid or flammable surroudings; avoid contact with any liquids. 6. The relationship between the output capacity and input voltage as following picture and diagram: |
Overload | Utmost using time |
20% | 60 minutes |
40% | 32 minutes |
60% | 5 minutes |
Long time overload is forbidden.
AVR/SVR series single phase RELAY CONTROL AC automatic voltage regulator , which is the classic style voltage regulator with analogue meter.It has the low energy consumption, the over-voltage protection, the low voltage protection, the over- current protection, the over-power protection, the over-temperature protection, the leakage protection and so on. It boasts for many kinds of protection functions integrated to one product. It also has the following functions: the selective time delay, the anti- impact, the Analogue display, the collection energy conservation and the environmental protection etc. This is a brand-new concept product which possess many new technologies! This series products simultaneously has applied for many technical monopolies.
FEATURES:
FEATURE : | Automatic voltage regulation Wide Input Voltage Range Large Capacity, High precision Protection against brownouts & over voltage Short circuit protection Analog indicators to show status of working,unusual and delaying Selectable delay time Build-in transformer:Toroidal transformer, E transformer selectable No Additional Waveform Distortion Global Voltage Customization |
APPLICATIONS: | TV-SET / HI-FI / DVD / FAX / Copy Machine / Printer/ Scanner /Air Conditioner/Computer /Test Equipment/Fridge /Lighting/ Equipment ETC |
PERFORMANCE AND SPECIFICATION:
Model | SVR-500 | SVR-1000 | SVR-1500 | SVR-2000 | SVR-3000 | SVR-5000 | |
Rated Capacity | 500VA | 1000VA | 1500VA | 2000VA | 3000VA | 5000VA | |
Phase | Single | ||||||
Transformer | E square transformer | ||||||
Indicator | analog meter | ||||||
Display Status | voltage and current | ||||||
Input | Voltage | 80~260 Vac | |||||
Frequency | 50/60 Hz | ||||||
Output | Voltage | 110/120/220/230/240 Vac optional | |||||
Precision | ±8% | ||||||
Protection | Overload | Yes | |||||
High temperature | Yes | ||||||
High/low voltage | Yes | ||||||
Short circuit | Yes | ||||||
Delay Function | delay / un-delay (180/6 seconds selectable) | ||||||
Efficiency | 98% | ||||||
Cooling system | Smart cooling | ||||||
Environmental | Operating temperature | 0 ~ 40 °C | |||||
Relative humidity | 10%~102% RH, non-condensing | ||||||
Storage temperature | -15 ~ 45 °C | ||||||
Appearance | AVR size (mm) | 240*125*155 | 340*205*255 | ||||
AVR N.W. (kg) | 2.60 | 2.80 | 3.50 | 3.80 | 8.50 | 10.00 | |
Qty/Ctn | 4 | 2 | |||||
Carton size (mm) | 550*300*190 | 510*390*300 | |||||
Carton G.W. (kg) | 10.50 | 11.50 | 14.20 | 15.50 | 17.50 | 20.50 |
PRECAUTIONS:
1. The voltage of network input must conform to the demand of AVR, for optimum operation. 2. Connect all plugs securely. 3. Always turn AVR power switch on first, the turn appliance power switch on.(Failure to do so may cause AVR fuse to blow) 4. For best results, do not use if overload condition exists. 5. Do not use in overly humid or flammable surroudings; avoid contact with any liquids. 6. The relationship between the output capacity and input voltage as following picture and diagram: |
Overload | Utmost using time |
20% | 60 minutes |
40% | 32 minutes |
60% | 5 minutes |
Long time overload is forbidden.
AVR-500VA-01 | AVR-1000VA-01E | AVR-1500VA-01 | AVR-2000VA-01 |
AVR-2000VA-02 | AVR-3000VA-01 | AVR-3000VA-02 | AVR-5000VA-01 |
AVR-500VA-01 | AVR-1000VA-01E | AVR-1500VA-01 | AVR-2000VA-01 |