FEATURES: Servo motor control
◆Remote control
◆Wide range voltage regulation
◆Automatic voltage regulation
◆Display:LED/LCD digital meter display
◆Protection functions:over voltage,overload,over temperature low voltage,time delay,Motor jammed protection
◆Waveform distortion:no additional waveform distortion
◆Dielectric strength:1500V/1min
◆Insulation resistance:≥2MΩ
SPECIFICATIONS
Input voltage | 140-260V AC |
Input frequency | 50/60Hz |
Output voltage | 220V AC/110V AC |
Output precision | 220V+/-3%,110V+/-6% |
Time delay | 3′s short time,180′s long time |
Load power factor | 0.8 |
Phase | single phase |
Operating temperature | 0-40℃ |
Storage temperature | -15℃-45℃ |
Operating relative humidity | 10%RH-102%RH |
Customize option for specification and availability please contact TAILEI |
DIMENSION WEIGHT
MODEL | QTY/CTN | DIMENSION(cm) | G.W.(kg) | N.W.(kg) | QTY IN 20′ft (PCS) |
SVC-E 500VA | 4 | 42.5*25.5*36 | 16.5 | 14.5 | 2868 |
SVC-E 1KVA | 4 | 50*27.5*39.5 | 19.5 | 18 | 2070 |
SVC-E 1.5KVA | 4 | 50*27.5*39.5 | 23.5 | 22 | 2070 |
SVC-E 2KVA | 2 | 60*33*25.5 | 17.8 | 16 | 1100 |
SVC-E 3KVA | 2 | 57*37.5*29.5 | 22 | 20 | 880 |
SVC-E 5KVA | 1 | 49*40*28.5 | 17.5 | 15 | 500 |
SVC-E 8KVA | 1 | 49*40*28.5 | 22.5 | 21 | 500 |
SVC-E 10KVA | 1 | 49*40*28.5 | 25.5 | 24 | 500 |
SVC-E 15KVA | 1 | 49.5*53*82 | 67 | 60 | 130 |
SVE-E 20KVA | 1 | 49.5*53*82 | 72 | 65 | 130 |
SVE-E 30KVA | 1 | 50*55*92 | 85 | 76 | 105 |
PRECAUTIONS:
1. The voltage of network input must conform to the demand of AVR, for optimum operation.
2. Connect all plugs securely.
3. Always turn AVR power switch on first, the turn appliance power switch on.(Failure to do so may cause AVR fuse to blow)
4. For best results, do not use if overload condition exists.
5. Do not use in overly humid or flammable surroudings ; avoid contact with any liquids.
6. The relationship between the output capacity and input voltage as following picture and diagram:
Overload | Utmost using time |
20% | 60 minutes |
40% | 32 minutes |
60% | 5 minutes |
Long time overload is forbidden.
FEATURES: Servo motor control
◆Remote control
◆Wide range voltage regulation
◆Automatic voltage regulation
◆Display:LED/LCD digital meter display
◆Protection functions:over voltage,overload,over temperature low voltage,time delay,Motor jammed protection
◆Waveform distortion:no additional waveform distortion
◆Dielectric strength:1500V/1min
◆Insulation resistance:≥2MΩ
SPECIFICATIONS
Input voltage | 140-260V AC |
Input frequency | 50/60Hz |
Output voltage | 220V AC/110V AC |
Output precision | 220V+/-3%,110V+/-6% |
Time delay | 3′s short time,180′s long time |
Load power factor | 0.8 |
Phase | single phase |
Operating temperature | 0-40℃ |
Storage temperature | -15℃-45℃ |
Operating relative humidity | 10%RH-102%RH |
Customize option for specification and availability please contact TAILEI |
DIMENSION WEIGHT
MODEL | QTY/CTN | DIMENSION(cm) | G.W.(kg) | N.W.(kg) | QTY IN 20′ft (PCS) |
SVC-E 500VA | 4 | 42.5*25.5*36 | 16.5 | 14.5 | 2868 |
SVC-E 1KVA | 4 | 50*27.5*39.5 | 19.5 | 18 | 2070 |
SVC-E 1.5KVA | 4 | 50*27.5*39.5 | 23.5 | 22 | 2070 |
SVC-E 2KVA | 2 | 60*33*25.5 | 17.8 | 16 | 1100 |
SVC-E 3KVA | 2 | 57*37.5*29.5 | 22 | 20 | 880 |
SVC-E 5KVA | 1 | 49*40*28.5 | 17.5 | 15 | 500 |
SVC-E 8KVA | 1 | 49*40*28.5 | 22.5 | 21 | 500 |
SVC-E 10KVA | 1 | 49*40*28.5 | 25.5 | 24 | 500 |
SVC-E 15KVA | 1 | 49.5*53*82 | 67 | 60 | 130 |
SVE-E 20KVA | 1 | 49.5*53*82 | 72 | 65 | 130 |
SVE-E 30KVA | 1 | 50*55*92 | 85 | 76 | 105 |
PRECAUTIONS:
1. The voltage of network input must conform to the demand of AVR, for optimum operation.
2. Connect all plugs securely.
3. Always turn AVR power switch on first, the turn appliance power switch on.(Failure to do so may cause AVR fuse to blow)
4. For best results, do not use if overload condition exists.
5. Do not use in overly humid or flammable surroudings ; avoid contact with any liquids.
6. The relationship between the output capacity and input voltage as following picture and diagram:
Overload | Utmost using time |
20% | 60 minutes |
40% | 32 minutes |
60% | 5 minutes |
Long time overload is forbidden.